ETID – MR 80mm – 250mm Fire Break Fixing

Stainless Steel “one piece” tubular bodied hammer in anchor. Typically used in applications where horizontal or vertical fire barriers are required. This fixing type offers a higher fire protection than other fixing types when applying a mineral wool Lamella fire break within an external wall insulation system. Typically specified when fixing into substrates like concrete, concrete blocks and brickwork.

Used for fixing Rockwool Lamella fire barriers in EPS and Phenolic systems where required. Fixing frequency is 2 per 1m length of Lamella. This fixing is secured by shank compression and relies on being forced into a hole smaller than its diameter.

  • 90 – 300mm

  • 250

Mechanical Fixing of Insulation to Various Substrates

Mechanical fixings or anchors play an important function in the way in which External Wall Insulation Systems perform under building and dynamic loadings. The role of the fixing is far greater than simply holding the insulation in place until the render is applied, it has to accommodate movement within the structure, positive and negative wind pressure and supporting the self-weight of the system to name a few key functions.

There are a number of different fixings that can be used and it is important to select the fixing for the application and in some instances this requires on site pull out tests to be completed to determine the performance of the fixing with the substrate.

Based on site conditions and location along with site based test results, a specific fixing pattern may be required. Please contact the Benx technical team for advice.

All masonry based EWI fixings are tested and Certified in accordance with ETAG 014 ‘Plastic Anchors for ETICS’. Within this standard there are 5 categories for which the fixings can be Certified as being acceptable to be used in and these can be seen in the table below. If a substrate is not categorised then on site testing must be done.

Technical Information

  • Anchor Body Material

    Stainless Steel

  • Pin Material

    N/A

  • Hammer or Screw Set

    Hammer

  • Minimum Embedment Depth

    50 mm

  • Drill Hole Diameter

    8 mm

  • Point Thermal Transmittance

    0.002 W/K

  • Length

    90 – 300mm

  • Quantity Per Box

    250